Ruskin dampers. The standard finishes described herein represent those finishes usually selected, specified, or required for most. Ruskin dampers

 
 The standard finishes described herein represent those finishes usually selected, specified, or required for mostRuskin dampers  A 1" (25) diameter jackshaft is normally used for

©Ruskin 2002 FRAME QTY. Ruskin’s low leak control dampers can save building owners up to $30 per damper 1 annually by providing tight sealing of outside air openings. G Bolt Circle Diam. Catalog. Steel construction with aluminum paint finish. With Seals Dampers 40" (1016) and under – 2 pieces of 18 gage steel. See “Smoke Damper Multiple Section Detail” spec sheet for details. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. Fusible Link which is included at no extra charge. The EFL is STANDARD on all fire/smoke dampers ordered with electric actuators. (Consult Ruskin for detailed CSI MasterFormat Specification. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. or N. Learn more about the FSD60 and its installation. 5 Hour for use in 2 Hour Walls. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. The CD40x2 has an 8" frame and aluminum construction. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. The FSD60FA da mper may be installed. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. g. The damper is rated for maximum velocity of 2,000 fpm (10. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. TDP05K Placement Tool. angles together at corners of dampers. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Dampers shall incorporate a dish-shaped circular blade mounted to internal slide-Ruskin CD450 is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Warranty claims under this Limited Warranty should be referred to: Ruskin 3900 Dr. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). These same finishes provide extended weathering resistance similar to adjacent building surfaces. g. The ELBD375I Automatic Intake Dual Combination aluminum louver combines a drainable blade louver and an intake backdraft damper in a nominal 9" frame depth. 165°F or 212°F (74°C or 100°C) (specify temperature) fusible volume adjustment options are available. Space fasteners 6" (152) on center and a maximum 2" (51) from the ends of the joining sec-tions or from each corner. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. used in conjunction with Ruskin fire/smoke dampers. When used in fan discharge applications, damper should bethe damper frame. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Swartwout series model 914 Heavy Duty Fiberglass Round Control Damper • Accurate control of airflow through the round duct • Designed specifically for corrosive environments • Premium constructed Vinyl Ester, Flange Mounted, single piece blade has 3 frame styles • Designed to withstand pressures up to 30" wg Differential PressureRuskin's premier damper for medium pressure commercial and industrial HVAC systems offers the lowest leakage available with a standard, commercial built damper. Ruskin Green Products. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica-tion 511 and comply with the requirements of the AMCA Certified Ratings Program. Ruskin furnishes, installs, and factory commissions actuators from a diverse lineup of manufacturers offering 2-position, 3-position, or modulating control. Greaves Rd. FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. Dynamic fire dampers shall be Ruskin model DFD60-3. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. The new DC "data center" models are high-performing airfoil blade type, and offer the lowest AMCA Class 1A leakage rating for energy savings. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. 5 Hour. It also features: Frame corners that are internally braced to reduce racking. Dampers shall be in all respects equivalent to Ruskin model IL35. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. L501). Dampers shall be designed for maximum 1500 fpm spot velocities and up to 4" w. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. FSD36 126"x 96"or 72"x 122" 4"w. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec-ommended maximums. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERSThe FSD60 Combination Fire/Smoke Damper are both UL555 and UL555S Classified, and rated as a 1-1/2 hour fire damper and a Leakage Class I Smoke damper. into damper blade and not a secondary operation. 2. Some of the approved ceiling designs are L501,. Ruskin offers threeII-G-Angle-514/Replaces II-IBD Style G -109 ©Ruskin 2014 DYNAMIC FIRE DAMPERS See label on damper for maximum air flow and pressure. Marketing Literature; Case Studies;. Do not weld or fasten angles together at cor-ners of dampers. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade Louver and Architectural. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance. 3900 Dr. 3900 Dr. Masonry/Wall or Floor: #10 self-tapping concrete screws. 2. Grandview, MO 64030 View our location on Google Maps Phone: 816. For up-to-date information visit CFD . The CD60 offers sturdy, steel construction with an interlocking frame design, enabling it to lock together without bolts, screws, or rivets that could shake loose. It features: For use in static systems Galvanized steel construction. UL 555/555S 1. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. Higher velocities are not recommended for outside air openings, due to water penetration concerns. ©Ruskin February2016 Model FSD60GA and FSD36GA series meet the requirements for combination fire and. Rectangular Silencers. Dampers shall be in all respects equivalent to Ruskin model CBD6. Standard, 1 1/2 and 3 hr. be-csd-thailand@jci. When installed as shown, they provide appropriate protection for air inlet or outlet penetrations in the ceiling membrane of floor/ceiling and roof/ceiling assemblieslabel and is classified as a static damper for use in HVAC systems that shut down during a fire. Windstops all around. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. dampers. 3. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. As a Corridor Damper it is designed to be used in openings in the ceilings ofRuskin anuary 2021 Page 2 1. lbs. Pressure drop and free area may vary. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Learn more about the FSD60 and its installation instructions from this document. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Fire dampers shall be Ruskin model FD35. A 1" (25) diameter jackshaft is normally used for. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. (2) 1/4-20 Nuts 2. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. The webpage provides the specifications and features of the Ruskin® CD80AF1 and CD80AF2 industrial control dampers, which are designed for heavy duty applications and high temperature environments. back pressure depending on damper size. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/ Steel Stud Wall. Title: CDRS82- Spec Author: Ruskin Created Date:The CFDR7T is UL555C Classified Ceiling Fire Damper for wood construction. Haldeman is a stocking Manufacturer Representative and Distributor of HVAC products since 1933. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. 5Hr » Combination Fire/Smoke Dampers 3Hr » Smoke Dampers » Corridor Dampers » 1. g. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. GENERAL INSTALLATION NOTES 1. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Louvers & Architectural. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. We are the leading manufacturer of air and sound. These louvers are popular for warehouse applications and other structures in which you want to close the airflow without the use of a damper. of damper with minimum of 20 in. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. damper actuators are UL listed for smoke control dampers or for combination fire/smoke rated dampers. Damper shall be Ruskin model BTR82. of damper with minimum of 20 in. The damper shall be rated for dynamic closure at 2000 fpm (10. SP200 Switch Package to allow remote indication of damper blade position. The Diffuser Radiation Shield, which allows any manufacturer's lay-in style steel ceiling diffuser (subject to gage and dimension limitations) to be installed in UL Classified F/C or R/C assembly with Fire. Maximum Damper Width (A Dimension) Maximum Damper Width (A Dimension) AREA FACTOR TABLE EXAMPLE: 1. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Rev. Name. After 15 minutes, the damper is closed and reopened. Standard features vary by model to make application selection straightforward. (1. UL approval for dual directional air flow. Ruskin round and oval solutions are perfect for applications utilizing spiral duct, or transitioning from rectangular to round. Figure 5. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. Hours: 9am - 5pm CDT M-F. Press and Drag to Scroll. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. lbs. Various relief air control settings are created by simple. Ruskin August 2020 Page5 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. 4 inches w. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. D-DIA. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood Factory or field supplied plenums Assembly designed to accept grilles with up to 2 1/2" grille depth with OBD Through ceiling. Page 1 INSTALLATION SUPPLEMENTS Horizontal Installation – 90"w x 91"h (2286 x 2311) or 114"w x 38"h. g. 3 sq. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Noise Control. Pressure limitations shown above allow maximum blade deflection of 1/180 of span on 60" (1524) damper widths. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Has airfoil blades, which have greater strength, provide superior sealing, and produce less noise. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. 25" w. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. F. The CFD7 is UL555C Classified Ceiling Fire Damper for wood construction. g. 4 inches w. max. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. The Ruskin Company’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Access Doors. a. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Ruskin provides perfect control Fire Smoke Dampers. It features: Vertical blades. Ruskin smoke damper and actuator assemblies qualify. b. Ruskin® A 0 Page 1 CD60CE Critical Environment High performance 316 stainless steel airfoil blade damper AMCA Class IA Leakage Rated The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. Static only damper labels are not permissible. b. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. 5. Torque applied holding damper closed at 10 in. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. angles together at corners of dampers. See “Combination Fire Smoke Damper Multiple Section Detail” specPerfect for a Wide Variety of Applications. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. CFD7T - 2"x4" Truss Assemblies (Ref. Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. Our History. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Noise Control. for dampers up to 17. Shims should be used between damper frame and opening or duct to. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. dampers are for use in dynamic (fans on) or static (fans off) sys-tems. These combination fire and smoke dampers are designed for installation with the blades running horizontally. 11-17-20. Higher velocities are not recommended for outside air openings, due to water penetration concerns. This model offers the lowest AMCA leakageRuskin® is an authority in Air Distribution and Air Control products such as dampers, louvers and silencers. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Greaves Rd. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Dampers may tolerate higher pressures and velocities than those listed here. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. As an option, qualification for use in Nuclear. g. of 8. • Fire smoke dampers larger than single section may require multiple actuators. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. SP100: Dampers shall be equipped with factory installed damper position indication switch package. 765. Ruskin® offers a comprehensive guide to its commercial dampers, including product features, specifications, installation instructions, and 3D Revit® files. Spec CBD4-507/Replaces CBD4-92000 ©Ruskin 2007 *Unit furnished approx 1/4" (6). • Fire smoke dampers larger than single section may require multiple actuators. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. Ceiling Fire Dampers UL Classified Radiation Dampers Underwriters Laboratories has classified hundreds of specific Floor/Ceiling (F/Cs) and Roof/ Ceiling (R/Cs) and established Fire Resistance Ratings for each design ranging from 1/2 to 5 hours. Pressure drop and free area may vary. Unequal section sizes. 125" (3. Damper Width “A” Dimension in inches ()The CDRI95 Round Isolation Damper is designed for round duct work capable of 20" w. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. All installations shall be in accordance with manufacturer's published installation instructions. Industrial FAQs. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. w. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. It features: • Galvanized steel construction • Class II leakage rating • Low torque operationequal to the damper width of two or more adjoining damper sec-tions. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. Axles that positively lock to blades without screws or welds. CD60 | Galv. For proper operation, damper must be installed square and free from racking. In addition, the DC models have. This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Zone Control. The Damper part prices in this catalog do include freight within the contiguous 48 states. cealed in the frame. The CD82HT Industrial Control Damper has an 8" frame. It is Leakage Class I classified and features: UL555S Class I. The damper/sleeve assembly is factory wrapped with ceramic fiber insulation. The CD51 can be utilized in systems calling for less than 10 cfm/sq. Axles that positively lock to blades without screws or welds. 081” thick extruded aluminum at approximately 4” c-c spacing. Product offerings include Air Control & Distribution products,. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and an EP (electro/pneumatic) switch. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. The SDRS25 is a UL555S Classified round smoke damper. ©Ruskin 2000 3900 Dr. Access Doors. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Greaves Rd. CDR25 and CDO25 dampers are round and oval volume control dampers. Static only damper labels are not permissible. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. A. g. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. The unit has encapsulated iris segmented blades and integral air pressure taps for great flow control and validation. 7447 Toll Free: 800. to. of damper with minimum of 20 in. The 316SS construction offers excellent corrosion resistance. Greaves Rd. The CFD8 is UL555C Classified Ceiling Fire (Radiation) Damper (CABS. The CD40 Series has 6" wide V-grooveThe PFL is a UL Classified heat responsive device used in conjunction with Ruskin fire/smoke dampers. for dampers up to 6 sq. It locks together without bolts, screws, or rivets that could shake loose. g. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. Ruskin Literature. 765. Dampers shall be in all respects equivalent to Ruskin Model CD40. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. Link Bar 5. 761. 6) 304tested and classified Ceiling Dampers (also called Ceiling Fire Dampers or Radiation Dampers) to provide fire and heat protection where HVAC components penetrate the ceiling membrane. g. All calculations are with external mounted actuators and accessories. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. g. Offset single blade design lets Ruskin engineers calibrate the damper operation to exact customer specification. Enter the Pressure Drop Chart at the determined area factorRuskin April 2021 Page 3 DAMPER SLEEVE DIMENSIONAL DATA The drawings show the position of the damper mounted in the factory sleeve. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. Dampers shall be in all respects equivalent to Ruskin model CBD6. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. Every damper is built with performance in mind and tested per AMCA standards. Use "Mount With Arrow Up" label as a guide for proper damper orientation. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). Mounting angles must overlap the partition a minimum of 1" (25). II. See “Combination Fire Smoke Damper Multiple Section Detail” spec Ruskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. g. 0 psi. 3. • Fire smoke dampers larger than single section may require multiple actuators. When you need to "dial in" branch air flow, Ruskin Model VFBD35 Value Flo "IRIS" Balancing Damper is well suited for ease of installation and labor savings. 4 psi respectively. Example: Maximum design total pressure of 8. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. (Dampers with V-Groove blades are structurally designed for velocities to 2000 FPM and above. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Noise Control. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. It features: AMCA Class 1A leakage for energy savings R value – 2. Carbon steel construction. Their line includes duct smoke detectors, flanged breakaway connections, fire damper angles, auxiliary switches, and more. 8) galvanized steel struc-Products. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. (2) ‘S. Figure 5. It also features: Frame corners that are internally braced to reduce racking. GRANDVIEW, Mo. Round Control Dampers. 075 lb/cu ft air. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Location of Damper in Ductwork Smoke Dampers must be placed in the ductwork so the closed blades are within 24” (610) of the smoke barrier and before any duct inlets or outlets (access doors not included). Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Pottorff is a leading manufacturer of AMCA- and UL-certified HVAC louvers and dampers for commercial applications. 5. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. (0. g. Damper frames Dampers shall be constructed with premium vinyl ester resinsThe FD60 is a UL555 classified, 1-1/2 hour rated, multiblade fire damper. Elevated temperature categories begin at 250°F and increase in increments of 100°F. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. g. Damper Dia. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. 16 (per ASTM C1363-2011) Thermal break in blade eliminates any thermal path, reduces condensation Mechanically fastened blade edge seals for longevity Shake proof. g. Their line includes duct smoke. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications.